tip-pressure-washer-math
Use when sizing pressure-washer nozzles or planning a washing job — cleaning units (PSI×GPM) classification, orifice flow math with pump dead-head warnings (demand >1.05× rated GPM), dilution ratio mixing for downstream injection, and per-surface plans (concrete/wood/vinyl/car) with tip angle, standoff distance, and pre-treat chemistry.
Tip & Pressure Washer Math
A 3000 PSI 2.5 GPM washer with the wrong tip is a worse tool than a 2000 PSI 3 GPM washer with the right one. Nozzle orifice size — not the pump's sticker — decides the pressure you actually hit and the flow you actually get. Too large a tip and pressure sags while the unloader chatters; too small and you starve the pump. This skill does that arithmetic plus the mixing math and per-surface doctrine that turns a pressure washer from a paint-stripper into a controllable cleaning instrument.
When to Use
- Buying or comparing pressure washers — cleaning units (PSI × GPM) is the honest metric, not peak PSI
- Choosing a quick-connect tip (0/15/25/40° fan or turbo nozzle) or replacing lost ones by orifice size
- Checking whether a turbo/rotary nozzle will starve or overload the pump
- Mixing detergents, degreasers, or bleach-based house washes — concentrate:water ratios into a tank or injector bottle
- Planning the wash for concrete driveways, wood decks, vinyl siding, or a car without etching concrete, furring wood, or stripping paint
The Method
# Compare machines honestly
python3 scripts/tip_math.py units --psi 3000 --gpm 2.5
# Nozzle sizing + pump-feed check (the warning fires when the tip
# demands >1.05x the pump's rated flow — dead-head/sag territory)
python3 scripts/tip_math.py orifice --size 4.0 --psi 3000 --rated-gpm 2.5
python3 scripts/tip_math.py orifice --list
# Chemical mixing: 1:9 concentrate:water into a 5 gal tank
python3 scripts/tip_math.py dilute --ratio 1:9 --tank-gal 5
# Per-surface plan: psi band, tip, distance, pre-treat
python3 scripts/tip_math.py plan concrete
python3 scripts/tip_math.py plan wood
python3 scripts/tip_math.py plan vinyl
python3 scripts/tip_math.py plan car
Orifice Table (flow = size × √(PSI/4000))
| Size | GPM @ 2500 | GPM @ 3000 | GPM @ 4000 |
|---|---|---|---|
| 2.0 | 1.58 | 1.73 | 2.0 |
| 2.5 | 1.97 | 2.17 | 2.5 |
| 3.0 | 2.37 | 2.60 | 3.0 |
| 3.5 | 2.76 | 3.03 | 3.5 |
| 4.0 | 3.16 | 3.46 | 4.0 |
| 5.0 | 3.95 | 4.33 | 5.0 |
| 6.0 | 4.74 | 5.20 | 6.0 |
| 8.0 | 6.32 | 6.93 | 8.0 |
A "4.0" tip flows 4 GPM at 4000 PSI — at lower pressure the same orifice passes less: size × √(PSI/4000). Turbos consume like a ~0° equivalent and derate effective pressure 20-25%; step down one size when adding one.
Dilution Doctrine
- Downstream injector (after pump): typical draw 10:1, tank mix = what you want ON the surface × 10. Harsh chemistry stays out of the pump.
- Upstream (through pump): only pump-safe chemistry; shorter hose runs dilute less.
- Concrete pre-treat: alkaline degreaser 1:5-1:10, dwell 5-10 min.
- House/vinyl: bleach-based soft wash 1:9-1:12, low pressure, bottom-up apply, top-down rinse.
- Car: pH-neutral foam 1:9-1:20, foam cannon, touch wash beats blast.
Surface Ceiling Table
| Surface | PSI band | Tip | Standoff |
|---|---|---|---|
| Concrete | 2500-4000 | 25-40°, turbo for stains | 4-8 in stains / 12 in rinse |
| Wood | 1200-1500 | 25-40°, with the grain | 12-18 in |
| Vinyl | 1300-1600 | 40°, bottom-up apply / top-down rinse | 18+ in |
| Car | 1000-1900 | 40° or foam cannon | 12-24 in |
Common Pitfalls
- Chasing peak PSI. 1 GPM cuts job time more than +1000 PSI. Flow is time; pressure is impact. Compare cleaning units.
- Oversized tip, sagging pressure. A tip flowing more than the
pump's rating dead-heads the pump and cycles the unloader (chatter).
The
orificecheck fires at >1.05× rated. - 0° red tip on anything soft. One pass can cut a line into concrete or a groove into wood. 0° is for stubborn spot stains only.
- Bleach through the pump. Run bleach-based mixes downstream only; it corrodes the pump head and seals.
- Fanning the wand on wood. Cross-grain passes fuzz the surface; keep the fan moving with the grain and step back to reduce PSI.
- Washing vinyl top-down. Apply bottom-up (streak control) and rinse top-down, or you get zebra lines behind you.
Verification Checklist
- Cleaning units computed and class identified for comparisons
- Orifice flow at working PSI checked against pump rated GPM (no >1.05× demand)
- Dilution math matches the injection type (downstream ×10 draw)
- Surface plan respects the PSI ceiling and tip angle
- 0° tip justified (spot stain) or swapped for 25°+
- Downloads
- Security audit
- Pass
- Last updated
- 1mo ago
- Current version
- v1.0.0
- License
- MIT-0