electrical-circuit-detective
Use when a breaker keeps tripping, an outlet went dead, or you wonder if a circuit can take one more appliance. Computes real circuit load with the 80% continuous rule, routes dead outlets (GFCI cascade, backstab failure), separates overload vs short vs ground-fault trip patterns, and names the exact point to call an electrician.
Electrical Circuit Detective
Overview
Residential electrical problems come in three everyday shapes: a breaker that keeps tripping, an outlet that suddenly went dead, and "can I plug this in here?". All three are answerable with arithmetic and a diagnostic tree before anyone opens a panel — and most trips and dead outlets have boring, fixable causes (overloaded 15A kitchen circuit, tripped GFCI hiding under a table, failed backstab connection).
This skill gives you the load math (watts ÷ volts = amps, 80% continuous rule), a ~45-appliance wattage database, a trip-pattern decoder, a ranked dead-outlet flow, and hard STOP gates for the situations that are genuinely dangerous.
Scope: diagnosis and planning. Not panel work. Anything inside the breaker panel, anything involving aluminum wiring, and anything after a "burning smell / scorch mark / tingle" report is electrician territory — the skill tells you that immediately instead of walking you deeper.
When to Use
- A breaker trips repeatedly and you want to know WHY before resetting it again
- One or several outlets went dead and the breaker looks fine
- Planning a new appliance (space heater, air fryer, EV charger, workshop tool) and asking "will this circuit take it?"
- You want to map which outlets are on which breaker (the circuit map nobody has)
- An outlet is warm, buzzing, discolored, or a plug falls out of it → skip to Safety Gates
Don't use for: outdoor/overhead service drops, sub-panel installation, EV charger hardwire sizing at 40A+ (needs a load calc per NEC 220.83 — flag an electrician), or anything commercial 3-phase.
Safety Gates — STOP Before Anything
Read these before touching anything:
- Burning smell, scorch/char marks, melted plastic, hot outlet face → turn the breaker OFF, leave it off, call an electrician today. Do not diagnose-live.
- Tingle or shock from any surface → breaker OFF, electrician, and treat wet floors as live. Do not test by touching again.
- Buzzing/sizzling at the panel, rust, or scorch at breakers → electrician only. Panels are never a DIY surface.
- Aluminum branch wiring (houses ~1965-1973, "AL" stamped on cable sheath, oxidation-capped wires) → any connection work is specialist work (AlumiConn/CopAlum). Detect and stop.
- Water contact (flooded basement, leak above an outlet) → kill the circuit first, then diagnose.
- Rodent damage suspected (attic/garage, gnawed sheathing) → electrician; damaged insulation can energize the box.
Everything below assumes: dry hands, rubber-soled shoes, non-contact voltage tester in hand, one hand in pocket when anything energized is near.
The Load Math (30 seconds)
amps = watts ÷ volts (120V normal outlets/lights, 240V dryer/range/AC/well)
safe continuous load = breaker × 0.80 ("continuous" = 3+ hours: heaters, servers, freezers)
| Breaker | 120V total | Safe continuous (80%) |
|---|---|---|
| 15A | 1800 W | 1440 W |
| 20A | 2400 W | 1920 W |
| 30A (240V) | 7200 W | 5760 W |
The 80% rule is why a 1500 W space heater + a 1500 W microwave on one 20A kitchen circuit trips: 3000 W = 25 A on a circuit whose honest all-day ceiling is 1920 W. Heaters, hair dryers, kettles, air fryers, and irons are the classic "invisible 1500s" — two on one circuit is always over.
Motor/compressor surge: fridges, freezers, sump pumps, compressors, and garage openers draw 2-3× nameplate for the first second. They don't usually TRIP breakers on surge (thermal-magnetic breakers tolerate brief inrush), but they explain "trips when the fridge cycles ON while the microwave runs".
Trip-Pattern Decoder
The timing of the trip IS the diagnosis:
| Pattern | Meaning | First move |
|---|---|---|
| Trips instantly when something is plugged/switched on | Short circuit or ground fault in that device/cord | Unplug it, reset, stays on = culprit found. If the breaker trips with NOTHING plugged in → wiring fault, electrician |
| Trips after minutes of running | Classic overload | Run circuit_doctor.py load on everything on that circuit |
| Trips only when two things run together (microwave + kettle) | Overload, marginal | Load math → move one appliance to another circuit |
| GFCI outlet RESET button pops, breaker stays on | Ground fault at plug level (moisture, worn appliance) | Unplug everything on that GFCI, reset, replug one by one |
| Trips when a motor starts (fridge/sump/AC) | Locked rotor / failing motor, or marginal overload | Note surge math; if fridge trips it ALONE → appliance fault |
| Trips at random times / at night | Water ingress, rodent chew, failing breaker, AFCI nuisance (aged motor) | Inspect attics/garage runs; swap loads; if random persists → electrician |
| Won't reset at all | Hard fault still present (or failed breaker) | Unplug everything, lights off; still won't reset → electrician |
| Trips only in wet conditions (bathroom, outdoor, sump) | Genuine ground fault — it's doing its job | Find the wet contact; never "fix" by removing the GFCI |
Dead Outlet Flow (ranked by probability)
- Tripped GFCI somewhere else on the circuit (~60% of "dead outlet" cases). GFCIs in garages/basements/bathrooms protect DOWNSTREAM regular outlets — sometimes in other rooms. Hunt every GFCI (test/reset buttons) in the house and press RESET. Outdoor + garage ones are the usual hidden suspects.
- Switched outlet: half the outlet dead? Plug a lamp into both halves and flip wall switches. Builders wire one half to a switch.
- Tripped/half-seated breaker: flip the breaker fully OFF then firmly ON. A breaker that "looks on" can be internally tripped.
- Failed backstabbed connection (very common in 1970s-90s builds): push-in connectors on the BACK of outlets fail and kill everything downstream on the run. Confirm with a non-contact tester: outlet dead, but the breaker is on, and other outlets on the run are ALSO dead in a line → it's the last WORKING outlet before the dead ones. Fix = re-terminate that outlet's wires on the side screws (breaker off, test dead first).
- Wire-nut failure in a junction box (thermal cycling loosens aluminum-era and old copper nuts) or a junction buried in an attic. Same downstream-dead signature.
- Broken outlet itself (springs tired, plug falls out, warmth) → replace the receptacle; warmth/scorch = electrician.
Script dead-outlet walks this tree interactively and tells you which box to open.
Circuit Mapping (do this once, label the panel)
- Phone note per breaker; plug a radio loudly into the mystery zone.
- Flip one breaker at a time (30s interval), note what dies (radio silence, lights, fridge hum stops).
- For each circuit, count outlets + note the big loads you find.
- Write it ON the panel door with a marker + masking tape label per breaker. Future-you needs this at 11 PM with a flashlight.
Using the Script
# Can this kitchen circuit run microwave + kettle + toaster?
python3 circuit_doctor.py load --volts 120 --amps 20 \
--items "microwave:1100,kettle:1500,toaster:900"
# Heater question: 1500W heater on a 15A bedroom circuit with lights
python3 circuit_doctor.py load --volts 120 --amps 15 --items "space heater:1500,led lights:40" --continuous
# Dead outlet diagnosis (interactive, ranked causes)
python3 circuit_doctor.py dead-outlet
# Trip pattern -> meaning
python3 circuit_doctor.py trip --pattern "minutes after running"
# What's in the appliance database
python3 circuit_doctor.py db
Output: amps drawn vs allowed, 80% ceiling, verdict OK / TIGHT / OVERLOAD, and which item to move. Unknown item names get nearest-match suggestions from the 45-entry database.
Common Pitfalls
- Counting nameplate watts as gospel for corded tools/microwaves — microwaves advertise OUTPUT (1000 W) but draw 1400-1600 W INPUT. The DB uses input draw. Rule: microwave input ≈ 1.4-1.6× advertised.
- Forgetting lights add up on 15A circuits — 20 old incandescent cans = 1200 W by themselves. LED retrofit (8 W each) frees the whole circuit.
- Extension cords don't add capacity — they derate it. A 16-gauge 50 ft cord on a space heater is a fire, not a solution. Cord math is in
references/circuit-guide.md. - "It held for a year" is not a load calc — breakers trip on heat; a marginal overload can survive winter and trip every day in summer heat.
- Replacing a tripping breaker with a bigger one — NEVER. The wire gauge is why the breaker is that size; a 20A breaker on 14-gauge wire is how house fires start.
- Resetting a GFCI repeatedly to "keep it working" — a GFCI that trips is reporting current going somewhere it shouldn't. Find the cause.
- Assuming the outlet closest to the panel is first — wiring order is rarely geometric. Map by dead-downstream evidence instead.
Verification Checklist
- Trip pattern classified (instant / delayed / GFCI / random) before any reset attempts
- Load math run with INPUT watts (not advertised output) and 80% rule for 3h+ loads
- Dead outlet: all GFCIs in house reset-checked FIRST, half-switched outlet ruled out second
- Panel map labeled after any discovery session
- Any safety-gate finding (smell/scorch/tingle/aluminum/water) escalated to electrician, breaker left OFF
- Nothing inside the panel opened by non-electrician hands