openclaw skills install @zw008/opcua-tapRead OPC-UA servers (opc.tcp) — browse the node tree, read node values with datatype/timestamp/status, bounded sampling, server info, best-effort alarm/condition surfacing, and threshold/anomaly health. Use when the task names OPC-UA, an opc.tcp:// endpoint, or a SCADA/PLC gateway exposing OPC-UA. Routes to the ot-aiops MCP server. Read-only. Do NOT use for IT/network gear, Kubernetes, hypervisors, or backups; for Modbus/S7/Mitsubishi/MTConnect/MQTT use the sibling *-tap skills.
openclaw skills install @zw008/opcua-tapRead-only OPC-UA telemetry + problem surfacing via the ot-aiops MCP server. Preview — validated against an in-process asyncua simulator, NOT live SCADA.
opc.tcp://host:4840), anonymous or user/pass.modbus-tap; Siemens S7 → s7-tap; Mitsubishi → mc-tap; CNC
machine tools → mtconnect-tap; MQTT/Sparkplug/UNS → sparkplug-tap;
Rockwell/Allen-Bradley EtherNet/IP → ethernetip-tap.industrial-diagnostics;
OEE / downtime / asset inventory → industrial-analytics.| Tool | Params | Returns |
|---|---|---|
opcua_server_info | endpoint? | {state, product_name, namespaces[...]} |
opcua_browse | node_id="i=85", endpoint?, depth=2 | [{node_id, browse_name, node_class, depth, parent}] |
opcua_read_node | node_id, endpoint? | {value, datatype, source_timestamp, status_code, good} |
opcua_read_many | node_ids[], endpoint? | [{node_id, value, ...}] |
opcua_subscribe_sample | node_id, endpoint?, samples=5, interval_ms=500, timeout_s=30 | {collected, samples[...]} (bounded) |
opcua_read_alarms | endpoint?, node_id="i=85", depth=4 | {active_alarms[...], active_count} |
opcua_read_history | node_id, endpoint?, start?, end?, max_points=1000 | {supported, count, values:[{value, source_timestamp, status_code}]} |
health_summary | endpoint?, node_ids[]?, thresholds? | {overall, counts, offenders[...]} |
anomaly_scan | node_id, endpoint?, samples=20, interval_ms=200, sigma=3.0 | {mean, stddev, outliers[...]} |
opcua_read_history is OPC-UA Historical Access (HDA): raw historical values
over a [start,end] ISO-8601 window (bounded). It returns {supported:false, note}
gracefully when the server does not historize the node. For bounded change-of-value
(only the changes, not every sample) use monitor_changes from industrial-analytics.
opcua_read_node(node_id="ns=2;i=5", endpoint="line1")
→ {"value":85.0,"datatype":"Double","source_timestamp":"2026-06-28T10:00:00Z","good":true}
ot-aiops init (add an opcua endpoint) · ot-aiops doctor · ot-aiops mcp.
Config: ~/.ot-aiops/config.yaml; secrets encrypted in secrets.enc, unlocked
via OT_AIOPS_MASTER_PASSWORD.
Read-only. Cert/message security (Sign/Encrypt) is roadmap — only anonymous + user/pass are validated. Endpoint text is sanitized; secrets are never returned. Missing a feature? 缺功能提 issue/PR 欢迎留言.