Install
openclaw skills install @zw008/iaiops-clinicalClinical-facility edition of iaiops — hospital / healthcare facilities as a distinct vertical from generic building management, with patient-safety framing. BACnet/IP BMS (isolation-room pressurization + medical-gas source monitoring), Modbus (medical-gas alarm panels / energy meters), OPC-UA (plant SCADA), plus the cross-protocol brain. Two signature safety checks: isolation_room_check (ASHRAE 170 / CDC negative/positive pressure) and medical_gas_check (NFPA 99 / HTM 02-01 O2 / medical air / vacuum source pressures). Use when the task mentions hospital, 医院, healthcare facility, clinical, 医疗设施, isolation room / 隔离病房 / 负压病房 / AII / PE, operating room / OR / 手术室, ICU, medical gas / 医用气体 / 医疗气体, oxygen / 氧气 / medical vacuum / 医用真空, or NFPA 99. Read-first; this edition's tool surface is read-only.
openclaw skills install @zw008/iaiops-clinical启动:IAIOPS_MCP=clinical / iaiops-mcp-clinical(= bacnet + modbus + opcua + 脑;
等价显式写法 IAIOPS_MCP=bacnet,modbus,opcua)。BACnet 需 extra:
pip install iaiops[bacnet]。典型现场:楼宇/暖通/隔离房压力走 BACnet BMS,医用气体
报警屏/表计走 Modbus,全院 SCADA 走 OPC-UA。
为什么单列 edition:医院设施科的关注点是患者安全(隔离房压力、医用气体), 买家/合规(NFPA 99、感控)与普通楼宇物业不同 —— 所以从
iaiops-building升格为独立 edition。工具复用同一套楼宇/BACnet + 脑,叠加两个临床安全检查。
isolation_room_check — 隔离病房压差合规(ASHRAE 170 / CDC:空气传染隔离 AII 负压、
保护性环境 PE 正压,≥2.5 Pa)。检出 reversed(反向,可上报安全事件)/breach/low_margin,
worst-first,每项引用读数。读数来自 bacnet_read_points 的压差 AI 点或历史库。medical_gas_check — 医用气体/真空源压力合规(NFPA 99 / HTM 02-01:O2/医用空气/N2O
~345–380 kPa、医用真空须够深)。检出 low_pressure / high_pressure / insufficient_vacuum /
critical,worst-first,引用数值。读数来自 BACnet AI 点或气体报警屏。or_environment_check — 手术室通风合规(ASHRAE 170 Table 7.1:温度 20–24°C、相对湿度
20–60%、换气 ≥20 ACH)。逐参数越界即 breach,worst-first,引用数值。读数来自 BACnet/BMS。bacnet_discover — Who-Is:本地 BACnet/IP 网上的设备bacnet_object_list — 设备的 object/point 列表bacnet_read_property — 单对象属性(默认 presentValue)bacnet_read_points — 所有 analog/binary/multistate 点的 presentValue(压差/气体压力快照)bacnet_cov_subscribe — 单对象有界 Change-of-Value 捕获bacnet_read_trend_log — 读设备 TrendLog 缓冲记录bacnet_write_property — [WRITE][HIGH][MOC] 写单对象属性(默认 dry_run=True + 双确认)modbus_read_holding modbus_read_input modbus_read_coils modbus_read_discretemodbus_detect_byte_order — 字节/字序自动探测modbus_list_templates / modbus_apply_template — 厂商寄存器模板 → 命名 tagmodbus_health_summary — 寄存器 vs 阈值分类opcua_server_info / opcua_browse / opcua_read_node / opcua_read_manyopcua_subscribe_sample opcua_read_alarms opcua_alarm_events(A&C 带时间戳) opcua_read_history(HDA)opcua_diagnose_connection — 连接失败归因;opcua_discover_tags 语义资产建模;
opcua_health_summary 阈值分类;opcua_anomaly_scan 有界统计异常扫描diagnose_dataflow downtime_root_cause downtime_root_cause_live downtime_triage
learn_cause_weights rca_corpus_from_maintenance historian_health alarm_bad_actors tag_health
subscription_health heartbeat_health alarm_flood_analysis alarm_cascade
alarm_rationalization_worksheetpdm_forecast —— 制冷/空压/真空泵趋势 + 到限时间data_quality_scorecard data_quality_fleet_rollupoee_compute downtime_events oee_multidim monitor_changesasset_inventory cross_protocol_asset_model adopt_alias_map diff_alias_mapbaseline_learn baseline_check baseline_record_change baseline_statuscompliance_mapping compliance_frameworks compliance_dengbao_levels
compliance_report compliance_evidence_bundle
historian_push export_data historian_query historian_coverage stream_publish uns_publish
stream_publish_event rca_narrate fleet_status fleet_incidentsplc_program_outline plc_program_xref plc_program_section plc_program_visibilityplc_program_snapshot plc_program_drift plc_program_history — 把「认可的那一版」
的结构记下来(文件 SHA-256 + 每个 block 的结构指纹:声明/调用/分支条件/定时器,不含行号、注释、
block 顺序,所以在文件顶上加一行注释不会把整份程序报成变更),之后问某一次导出动没动。
三个判词咬得很紧:identical 只由 SHA-256 相同得出;logic_changed 逐 block 指出哪一类变了;
changed_outside_extracted_structure = 字节变了而结构指纹全同 —— 多半是注释/排版,但这些 parser
是结构抽取不是文法,所以它不叫「仅文档」,也不构成放行。删历史只在 CLI(iaiops program forget):
删变更控制证据不该离 agent 只有一次调用。存的是 block 名 + 哈希 + 计数,不落声明、源码行和注释。verify_determinism — 把「拿掉模型、断网、同一份数据重跑、输出逐字节相同」跑出来:
固定数据集过一遍分析层,规范化后取 SHA-256,在本进程跑两遍、再在两个不同 PYTHONHASHSEED 的
全新解释器里各跑一遍(这一臂才抓得到集合/字典迭代顺序渗进结果),全程 socket 抛异常。
给 CSV/验证团队的是一条能写进 IQ/OQ 的测试用例,不是一句形容词。protocols_supported(产品能做什么)· site_readiness(这个站点今天能跑什么、还差什么;零联网)investigation_readiness investigation_open investigation_show
investigation_list — 「真出事时这个站能走到第几步、每个缺口还差什么」,以及对一个已过去的窗口
逐步走完并留档(不碰设备)。缺口分两种:你没供(给命令) 与 产品供不了。line_relation_declare line_relations_list mechanism_library_check
mechanism_library_list — 上下游由人声明(D25:线上下游共现是必然,推不出因果);
机制库按 ISO 14224 分 mode/mechanism/cause,可排除、绝不确认,
库里没有这条原因 → nothing_known(不是「无异议」)。protocols_supported → iaiops doctor → BACnet 先 bacnet_discover。bacnet_read_points 读隔离房压差 AI 点 → isolation_room_check;
读医用气体源压力点 → medical_gas_check。两者 worst-first,reversed/critical
优先处置。判定仅为结构性分析,现场 NFPA 99 报警屏/感控为准。downtime_triage;制冷/真空泵劣化用 pdm_forecast。bacnet_write_property 为唯一写工具,统一走 MOC:
risk=HIGH + 默认 dry_run=True + 改前值 undo + iaiops approve 具名审批双确认。
绝不对生命安全相关的暖通/气体系统未经授权下发。待核实 不得当既成事实)| 协议 | 库(pin) | 规范/版本 | 覆盖 | 传输 | 自测 |
|---|---|---|---|---|---|
| BACnet/IP | BAC0>=2023.6,<2026(extra,over bacpypes3) | BACnet/IP(read + 单点写) | BMS/暖通/压力/气体点 | UDP/47808 | ⚠️ mock;真 BMS 待核实 |
| Modbus-TCP | pymodbus>=3.5,<4 | App 1.1b3;FC 1/2/3/4/5/6/15/16 | 气体报警屏/表计/任意从站 | TCP/502 | ✅ |
| Modbus-RTU | pymodbus>=3.5,<4 + pyserial>=3.5 | Modbus serial (RTU) | 串口从站/表计 | RS-485/serial | ✅ socat PTY;物理 RS-485 待核实 |
| OPC-UA | asyncua>=2.0,<3 | OPC UA 1.0x(DA+HA+AC 子集) | 全院 SCADA / PLC 网关 | opc.tcp | ✅ mock+HDA |