Tp4
- Category
- MCP Tool Poisoning
- Confidence
- 95% confidence
- Finding
The overall primary purpose matches: it is a pure local unit converter covering the declared categories and does not use the network or extra permissions. However, the description specifically states support for Chinese and English unit names. In the code, non-temperature categories validate units strictly against abbreviation keys like km, m, kg, gb, ha, etc. Chinese unit names such as “千米” or “米” are not accepted as input. The NAMES mapping is only used to render output text, not to parse user-provided unit names. Only the temperature branch supports Chinese and English aliases like 摄氏度/华氏度 and ℃/℉. Therefore the description overstates multilingual input support, creating a meaningful description-behavior mismatch.
- Content