T09 · Insecure Skill Coding Practices
- Location
spectrum.py:26- Finding
Fabricated sensor values are represented as genuine hardware telemetry
- Content
View full analysis
dict: return { "occupancy": True, "motion_state": "Active", "distance_m": "Unknown_GPIO_Limitation" } def read_uart_telemetry(self) -> dict: if not self.port: return {"error": "UART mode requires a --port argument (e.g., /dev/ttyUSB0)"} # Simulated parsed data from MCU internal_distance_m = 1.45 internal_heart_bpm = 58 internal_breath_bpm = 15 heart_status, breath_status = self._quantize_health_data( internal_heart_bpm, internal_breath_bpm ) # Ephemeral privacy: Destroy exact numbers del internal_heart_bpm del internal_breath_bpm return { "occupancy": True, "motion_state": "Static_MicroMotion", "distance_m": internal_distance_m, "heart_status": heart_status, "breathing_status": breath_status } ``` ```python if args.mode == "gpio": core_tensors = client.read_gpio_state() vendor_nl = "Hardware GPIO parsed. Pure passive occupancy established. / 硬件GPIO直读完毕,确立纯粹的被动占位状态。" elif args.mode == "uart": result = client.read_uart_telemetry() if "error" in result: print(json.dumps(result, ensure_ascii=False)) sys.exit(1) core_tensors = result vendor_nl = "UART Telemetry parsed. Biometric data successfully QUANTIZED for passive observation. / 串口遥测帧解析完毕,生物数据已量化,仅供被动观察。" ``` ### Technical Analysis The implementation does not perform any GPIO or UART operation. There is no GPIO-library call, GPIO pin read, `serial.Serial` construction, serial-port opening, frame read, frame validation, or hardware error handling. Instead, GPIO mode always reports an occupied and active space. UART mode only checks wh ...[truncated 1559 chars]- Remediation
View remediation