searxng-search
Route web searches through local SearXNG, choose suitable engines for general, biomedical, technical, and current-news research, and periodically recheck engine health.
SearXNG Search
Search
- Use the configured SearXNG-backed
web_searchfor web research when available; verify that it returns results and identify its provider when the tool exposes that information. Do not assume SearXNG is active merely because it was configured previously. - Route by intent: use broad general-web search for discovery, primary publishers or databases for evidence, and domain-specific engines for technical or specialty questions. For Insub's biomedical work, prioritize primary literature and bibliographic sources (for example Europe PMC, PubMed, Crossref, OpenAlex, or arXiv when relevant); use more than one independent source for consequential claims. For software documentation, prioritize the project's official documentation and focused IT/Q&A engines. For recent events, use news engines and check publication dates. Treat these as source choices, not endorsements of every result.
- Use SearXNG engine shortcuts only after confirming the current inventory at
/config; shortcuts and enabled status can change. To target an engine, use SearXNG's!shortcutsyntax only when appropriate, and inspect which engines actually contributed results. A result from the aggregate response does not prove the intended engine returned it. - Inspect result title, publisher/domain, URL, date, and relevance before citing. Prefer primary sources, distinguish search snippets from source contents, open/read the source when possible, and corroborate important or biomedical claims. Search-engine availability is not a measure of source quality.
- If SearXNG is unavailable, empty, or dominated by upstream errors, distinguish local-service failure from individual-engine failure. Retry once with a narrower query or an alternate suitable engine; then use another available search route if needed and disclose the fallback. Do not repeatedly hammer CAPTCHA/rate-limited sources.
Engine health checks
- Refresh the inventory from the live local instance (
/config) before a health audit. Check representative engines when search failures recur, before relying on an old snapshot for important research, and otherwise about quarterly; do not probe all engines on every search. - Select a small, relevant set from the live inventory: general web, news, technical documentation/Q&A, and scientific-publication engines. Include biomedical sources when relevant. Include only engines actually configured, and note enabled state; do not change configuration as part of a health check.
- Test each selected engine individually using a neutral, category-appropriate query and SearXNG's JSON search endpoint (
/search?q=!<shortcut>%20<query>&format=json). Use low concurrency (at most 4) and a reasonable timeout. Match results by the engine attribution fields (engineorengines), recordunresponsive_engines, response time, and a small title/domain sample. Use a query appropriate to the engine: a general programming query does not establish that a science, weather, translation, or specialty source works. - Classify outcomes as results, upstream error/suspension, or empty/inconclusive. Empty responses are not proof of failure; distinguish CAPTCHA, rate limits, access denial, timeout, TLS, and parser errors. Validate answers/infoboxes against the requested task rather than treating any answer as success.
- Save dated audit output locally under
reports/or the active project, without credentials or sensitive query content. Compare with the previous audit, but describe the check as a small availability spot-check, not a quality benchmark. Avoid heavy full-inventory probing unless explicitly needed; do not disable/enable engines based only on one probe. - Use
references/engine-baseline-2026-10-08.mdonly as historical context. Recheck current state before recommending engines, since the attached one-query snapshot is not a current guarantee.
Current user-fit baseline
- For an ordinary broad search, start with currently working general-web engines and diversify if coverage is weak; the historical snapshot found Google CSE and DuckDuckGo Web returning results, while direct Google and DuckDuckGo were blocked/CAPTCHA and Brave was rate-limited.
- For biomedical/scientific discovery, begin with currently working literature databases and publication indexes. In the historical snapshot Europe PMC and arXiv returned results, while PubMed was rate-limited, Semantic Scholar had a parsing error, and OpenAIRE endpoints timed out. Verify current status and prefer the authoritative database directly for final evidence.
- For technical documentation, use official documentation search or currently responsive focused sources; the historical snapshot showed Stack Overflow, Ask Ubuntu, Super User, MDN, and Microsoft Learn returning results. Verify that a candidate actually fits the specific technology.
- Treat these recommendations as an initial shortlist, not fixed preferences: choose based on the request, live health, source authority, and result relevance.
- Downloads
- 183All time
- Security audit
- Pass
- Last updated
- 2w ago
- Current version
- v1.0.0
- License
- MIT-0
