iaqualink
Latest: v0.3.1
- Removed
skill-card.md.
iAqualink (iaqualink-mcp)
Tools for the user's own iAqualink pool/spa systems. Two system types are supported: iAqua (Jandy iAquaLink panels — pumps, heaters, set points, aux circuits, lights) and eXO (Zodiac salt chlorinators — chlorine production, boost, low mode, filter pump, heating, pH/ORP). Other devices on the account (robotic cleaners) are listed but not controlled.
Built from the open-source iaqualink-py client. Sign-in, the system list, iAqua status reads and the WebTouch panel tools have been seen working on a real RS panel. The iAqua
set_*commands, everything eXO and the chlorinator shape are still derived and not yet exercised live. If a write comes backsent-unconfirmed, say so plainly rather than claiming it worked.
Start here
iaqualink_list_systems→ serials and types. Most homes have one system; use its serial everywhere else.iaqualink_get_status { serial }→ temperatures, set points, equipment states (off/on/standby/enabled= heating), aux circuits with labels, lights, and chlorinator/chemistry where present.view: "full"adds light effect lists and the raw entries;view: "raw"is iAqualink's own response.iaqualink_healthcheckwhen something fails: it says whether a sign-in is configured and whether iAqualink accepted it.
Readings are in the system's own unit (unit: F or C; eXO is always °C).
An empty reading (null) means the sensor has nothing to report — e.g. the spa
temperature while the spa pump is off.
Changing things
| Want | Tool |
|---|---|
| pump / heater / solar on-off; eXO filter pump, production, boost, low, heating | iaqualink_set_equipment { serial, equipment, on } |
an aux circuit or light on/off (by number, aux_3, or its label) | iaqualink_set_aux { serial, aux, on } |
| dimmable light level (0/25/50/75/100) or color effect | iaqualink_set_light { serial, aux, brightness | effect } |
| pool and/or spa target temperature | iaqualink_set_temperature { serial, pool?, spa? } |
| eXO chlorinator output % | iaqualink_set_chlorinator { serial, percent } |
| run / stop a OneTouch scene (iAqua) | iaqualink_set_onetouch { serial, onetouch, on } |
| add a panel program (iAqua) | iaqualink_add_schedule { serial, circuit, start, stop, days } |
| change a panel program's times/days | iaqualink_edit_schedule { serial, page, row, circuit, start, stop, days, newStart?, newStop?, newDays? } |
| delete a panel program (no undo) | iaqualink_delete_schedule { serial, page, row, circuit, start, stop, days } |
| change or disable an eXO timer | iaqualink_set_schedule { serial, schedule, start, stop, rpm?, enabled? } |
Every write:
- Checks first. If the equipment is already in the requested state it
returns
status: "unchanged"and sends nothing. - Asks for confirmation. On clients without a prompt the first call returns
a
confirmation-requiredpreview and aconfirmToken; show the preview to the user, get their explicit yes in chat, then repeat the call with the token. If the pool's state changed in between, the token is refused (DRAFT_CHANGED) with a fresh preview — show that one instead. - Verifies.
confirmedmeans a re-read shows the change.sent-unconfirmedmeans iAqualink accepted it but the re-read did not show it yet — eXO systems apply changes asynchronously; tell the user and checkiaqualink_get_statusagain later. Do not blindly retry: iAqua pump/heater/aux commands are toggles.
Notes:
- Turning a heater on lets it heat to the set point; changing the set point alone does not turn the heater on.
- A color light's current color cannot be read back, so an effect change is confirmed only by the light being on.
iaqualink_set_chlorinatoruses an inferred request shape (not in the reference client) — trust it only when the result isconfirmed.
Schedules and scenes
iaqualink_list_schedules { serial }— on a Jandy AquaLink RS panel (iAqua): the panel's own programs (circuit, 24-hour start/stop plus the panel's text, run days, and the page/row each sits at), read through WebTouch. eXO: pump / chlorinator / aux timers. If WebTouch is unavailable the result says so (webtouchError) and shows the iQ20 fallback instead.- RS panel programs:
iaqualink_add_schedule,iaqualink_edit_schedule,iaqualink_delete_schedule. Edit and delete identify a program by exactly what the list showed (page, row, circuit, start, stop, days) — always list first. Times are 24-hourHH:MM; a stop earlier than the start runs overnight. Run days are the panel's:All,M,Tu,W,Th,F,Sa,Su,Wkdays,Wkends. The preview shows the list before and after;confirmedmeans a fresh re-read matched. Delete has no undo. - If a panel write aborts, the error says exactly what state the panel was left in (e.g. "in Edit mode with UNSAVED changes") — relay it verbatim.
- eXO timers:
iaqualink_set_schedule; a chlorinator timer must sit inside its pump timer's window, andenabled: falseclears a timer. iaqualink_check_panel— first stop when a schedule/OneTouch tool reports a dialog or a timeout, or the app shows the system offline: reports the cloud online flag and what the panel shows.edit_unsavedmeans the panel is in schedule Edit mode with unsaved changes; the owner must Save or discard them at the panel or in WebTouch — do not retry the write.iaqualink_list_pump_speeds/iaqualink_set_pump_speed/iaqualink_set_pump_speed_rpm— an RS panel's variable-speed pump. Pressing a named speed on the panel runs the pump at it at once, so "switch speed" and "change a speed's RPM" are separate tools; changing a speed that is not running runs it for a few seconds and then switches back.iaqualink_list_onetouch/iaqualink_set_onetouch— the panel's one-button scenes ("Spa Mode", "All OFF"), via WebTouch. The button is a toggle; it is pressed only when the scene is not already in the requested state.
Trouble
no_credential→ the user needs to setIAQUALINK_EMAIL/IAQUALINK_PASSWORD(or reconnect the hosted connector).credential_rejected→ the email/password is wrong. The server will not retry it (so the account cannot be locked); the user must fix it and restart or reconnect.- Rate limited → wait a minute; eXO systems in particular dislike fast polling.
- System
online: false→ the panel is offline from iAqualink's cloud; nothing can be controlled until it reconnects.