Install
openclaw skills install @1003429073/iso17025-lab-competence-guardAudit test/calibration lab documents against ISO/IEC 17025:2017 before release. Flags nonconforming reports, certificates, and quality records with clause-level citations and fix suggestions.
openclaw skills install @1003429073/iso17025-lab-competence-guardActivate when reviewing, generating, or publishing any of:
Each test report / calibration certificate must contain ALL of the following. Missing any one = nonconforming:
| # | Required Element | Clause |
|---|---|---|
| 1 | Title ("Test Report" / "Calibration Certificate") | 7.8.2(a) |
| 2 | Laboratory name and address | 7.8.2(b) |
| 3 | Unique identification of the report/certificate | 7.8.2(c) |
| 4 | Customer name and contact | 7.8.2(d) |
| 5 | Identification of the method used | 7.8.2(e) |
| 6 | Description and identification of the item tested/calibrated | 7.8.2(f) |
| 7 | Date of receipt of item and date of performance | 7.8.2(g) |
| 8 | Results, with units where applicable | 7.8.2(h) |
| 9 | Name of person(s) authorizing the report | 7.8.2(i) |
| 10 | Clear identification of which results relate to the item | 7.8.2(j) |
| 11 | Statement of conformity (if applicable), with rules/standards | 7.8.2(k) |
| 12 | Measurement uncertainty (where relevant) | 7.8.2(l) |
Calibration certificates additionally require:
| Issue | Clause Violated | Severity |
|---|---|---|
| Missing measurement uncertainty | 7.8.2(l), 7.8.3 | Critical |
| No traceability statement | 6.5 | Critical |
| Unlabelled opinion/interpretation | 7.8.5 | Major |
| Report signed by unauthorized person | 6.2, 7.8.2(i) | Critical |
| Equipment past calibration due date | 6.4.4 | Major |
| Method not validated for intended use | 7.2.2 | Major |
| Amendment without proper re-issue | 7.8.7 | Major |
| Absolute claims ("most accurate", "100% precise") | 7.8, advertising rules | Minor |
| Confidential data exposed | 4.2 | Critical |
| Nonconforming Term | Correct Term | Basis |
|---|---|---|
| "accuracy" (as a number) | "measurement uncertainty" or "trueness + precision" | VIM / ISO 5725 |
| "error = 0" | Report actual uncertainty | 7.8.2(l) |
| "permanently valid" | State specific validity/interval | 7.8.3 |
| "certified" (without basis) | "accredited" (only if accredited) | ISO 17011 |
| "best in class" | Remove or substantiate | Advertising |
【ISO/IEC 17025 Compliance Review】
Document type: xxx
Review date: xxx
Standard: ISO/IEC 17025:2017
✅ Conformant items: x
⚠️ Observations: x (recommend improvement, not blocking)
❌ Nonconformities: x (must be corrected before release)
--- Nonconformities ---
[1] Issue description
→ Clause violated: xxx
→ Suggested correction: xxx
--- Observations ---
[1] Issue description
→ Recommendation: xxx
【Conclusion】: PASS / FAIL (correct and re-review)
When the user submits a document for review, check it item-by-item against the rules above and produce the structured report.
For detailed clause text and edge cases, see references/iso17025-clauses.md.